11 connecting torch supply leads – Tweco Merlin 6000 Master PS User Manual

Page 30

Advertising
background image

INSTALLATION PROCEDURES

3-12

Manual 0-2568

OUTPU

T

OUTPUT

TO

TO

CON

TROL

CONTROL
MOD

ULE

MODULE

AIR

AIR

PLAS

MA

PLASMA

INPU

T

INPUT

N

2

PLAS

MA

PLASMA

INPU

T

INPUT

O

2

PLAS

MA

PLASMA

INPU

T

INPUT

PLAS

MA G

AS

PLASMA GAS

Ar/H

Ar/H

2

PLAS

MA

PLASMA

INPU

T

INPUT

OTHER Secondary

Gas Supply

N2 Secondary

Gas Supply

A-01342

Figure 3-17 Secondary Gas Connections

3.11 Connecting Torch Supply

Leads

The Torch Supply Leads interfaces the Master Power Sup-
ply to the Arc Starter Box. The Torch Supply Leads is
made up of individual hoses and cables that must be con-
nected.

NOTE

Refer to the Arc Starter Box Instruction Manual
0-2572 for details on installation of the Arc Starter
Box.

The Torch Supply Leads components connects directly
to a bulkhead inside the Master Power Supply and to con-
nections inside the right side panel. Connect the Torch
Supply Leads components per the following procedure:

WARNING

Primary power should NOT BE APPLIED when
working inside the power supply.

1. Open the front panel access panel to gain access to

the bulkhead.

2. Feed the four hose assemblies on the Torch Supply

Leads components through the boot on the front panel
of the Master Power Supply.

3. Connect the four hose assemblies onto the mating con-

nections at the internal bulkhead of the Master Power
Supply per the following figure.

Secondary

Gas Lead

Torch Supply Leads

Supply Leads Boot

Coolant Return

Lead

Coolant Supply

Lead

Plasma

Gas Lead

A-01447

Control Cable

Master Power Supply

Bulkhead

Figure 3-18 Leads Extension Hose Connections To

Master Power Supply

4. Connect the end of the Pilot Lead, two wires, to the

Master Power Supply per the following procedure:

a. Remove the right side panel from the Master

Power Supply.

b. Feed the Pilot Lead, two wires, through the small

strain relief at the front panel of the Master Power
Supply.

c. Remove the nut and star washer on the ground

terminal of the pilot connection inside the power
supply.

Advertising