Section 4: operation, 01 introduction, 02 operating controls – Tweco PakMaster 75XL Plus (CE) User Manual

Page 29: Section 4, Operation -1, 01 introduction -1 4.02 operating controls -1

Advertising
background image

Manual 0-2782

4-1

OPERATION

SECTION 4:

OPERATION

4.01 Introduction

This section provides a description of the Power Supply
operating controls and procedures. Identification of the
Front and Rear Panel components is followed by operat-
ing procedures.

4.02 Operating Controls

This subsection provides specific functional descriptions
of the Power Supply operating controls and indicators.

A. Front and Side Panel Features

1. Control Panel

All operator controls, except gas pressure adjustment,
are located on this panel. Power ON/OFF and RUN/
SET/LATCH switches; CURRENT control; indicators
for AC Power, TEMP, GAS, and DC.

A-02458

1

2

3

4

5

Figure 4-1 Front and Side Panel Connections

2. Access Panel

A panel for access to the bulkhead area containing
the torch connections.

3. Torch Leads Input

Hole in the front panel to feed the torch leads through
to the internal bulkhead connections.

4. Work Cable and Clamp

Work cable with clamp (factory installed).

5. Torch Leads and Spare Parts Kit Storage Area

Bracket connected to the side panel of the unit for use
in storing the torch, torch leads, work cable, and spare
parts kit when not in use. The spare parts kit fits into
the opening on the top of the bracket. The torch leads
and work cable wrap around the bracket for easy stor-
age.

B. Control Panel Features

A

A-03625

15

40

60

1

2

3

4

5

6

7

Figure 4-2 Operating Controls

1. Current Control (A)

Adjustment to set the desired output current between
15-60 amps. For drag cutting applications set the con-
trol between 15 - 35 amps. The unit has an automatic
fold-back circuit that limits current to 35 amps dur-
ing drag cutting.

2. ON /OFF

Power Switch

ON position supplies AC power to activate all sys-
tem control circuits. OFF position deactivates control
circuits.

3. RUN

/SET

/LATCH

Switch

RUN position is used for torch operation. SET posi-
tion used for setting gas pressure and purging lines.
LATCH position is used for specific applications (torch
switch can be released after main arc transfer).

4. AC Power

Indicator

Green indicator will blink ON then OFF for approxi-
mately eight seconds and then stay ON after the ON/
OFF power switch is set to ON. Indicates operating
power is present in the unit.

Advertising