Tweco PakMaster 75XL Plus User Manual

Page 29

Advertising
background image

Manual 0-2746

23

SECTION 4: OPERATION

Standard Shield Cup

Catalog No. 8-7500

Standoff Cutting Tip

Air/N2, 60 Amp

Catalog No. 9-7726

Gouging Gas Distributor

Catalog No. 8-7508

A-02473

Crown Shield Cup

Catalog No. 8-7507

Drag Cutting Tip

Air/N2, 35 Amp

Catalog No. 8-7503

Gouging Tip, Air

Catalog No. 8-7506

Gas Distributor

Catalog No. 8-7501

Electrode

Catalog No. 8-7502

Copper Shield Cup
Catalog No. 8-7496

Figure 4-7 Parts Selection (PCH-60)

B. Check primary power source as follows:

1. Check the power source for proper input voltage. Make

sure the input power source meets the power require-
ments for the unit per Section 2.03-A-4, Specifications/
Design Features.

2. Connect the input power cable (or close the main dis-

connect switch) to supply power to the system.

C. Gas Selection

Select desired gas (air or nitrogen). Make sure gas source
meets pressure and flow requirements (refer to Section
3.08, Gas Connections). Check connection and turn gas
supply on.

D. Work Cable Connection

Check for a solid and clean work cable connection to the
workpiece. The area must be free from paint and rust.

Make a solid work cable
connection to the work-
piece or cutting table

A-00925

Figure 4-8 Work Cable Connection To Workpiece

E. Torch Connection

Check that the torch is properly connected.

F. Power Supply On

Move the ON/OFF switch to ON position.

G. Select Output Current

Select the desired current output level for the operation:

• 15 to 60 amps for standoff cutting and gouging

• 15 to 35 amps for drag cutting

H. Set Operating Pressure

Move the RUN/SET/LATCH switch to SET position. Ad-
just the gas pressure to 60 psi (4.1 bar).

I. RUN/SET Switch

Set the RUN/SET/LATCH switch to RUN position.

The system is now ready for operation.

NOTE

For general cutting, use the RUN position which
provides normal touch operation where the torch
switch must be held throughout the main arc trans-
fer.

For specific applications, use the LATCH position
where the torch switch can be released after the main
arc transfer. The torch remains activated until the
main arc breaks from the workpiece.

Advertising