APPENDIX I: INPUT WIRING REQUIREMENTS

NOTES

The table above is based on the following output current and voltage: 130VDC @ 60A

An energy limiting fuse UL Class RK-1 (examples: BUSS LPS/LPN-RK or Gould-Shawmut AZK-A6K) should be
used to minimize damage to Plasma Cutting, Welding or power distribution equipment.

NEVER

use replaceable element fuses like UL Class H, or "one-time" fuses like UL Class K5.

Primary input power cable must have an outside diameter of 0.69 inches (17.5 mm) or greater.

Input

P ow er Input

Cur r ent Input

Recommended S izes (S ee Notes)

V oltage

Fr eq.

1-P h

3-P h

1-P h

3-P h

Fuse (Amps)

W ir e (AW G )

W ir e (Canada)

(V olts)

(Hz)

(kV A)

(kV A)

(Amps) (Amps)

1-P h

3-P h

1-P h

3-P h

1-P h

3-P h

208

50/60

12.5

11.2

60

31.1

70

40

4

8

4

8

230

50/60

12.5

11.3

54.1

28.3

70

35

4

8

4

8

240

50/60

12.6

11.4

52.3

27.5

60

35

6

8

6

8

380

50/60

13.9

12.4

36.5

18.9

45

25

8

10

8

10

415

50/60

13.9

12.6

33.4

17.5

40

25

8

12

8

12

460

50/60

13.9

12.7

30.1

16

35

25

8

12

8

12

575

Requires Transform er M odule

Line V oltages with Recom m ended Circuit P rotection and W ire S izes

(B ased on Table 310-16, 1987 National E lectric Code) and Table 4, Canadian E lectrical Code.