Tweco PCM - 102 Machine Torch User Manual

Page 22

Advertising
background image

INSTALLATION

3-4

Manual 0-2818

3. Connect the torch Negative / Plasma Lead to the bulk-

head connection inside the Power Supply.

4. Connect the Control (PIP) Circuit Connectors to the

mating connectors on the Adapter supplied on the
Power Supply (see Warning).

WARNING

The Adapter supplied with the Power Supply has
two additional Shield Connectors that are used for
Shielded Systems only. These two connectors are
not used and need to be taped out of the way to
prevent contacting the Negative & Plasma or Pi-
lot Leads.

5. Remove the top nut and washer from the Pilot

Stud.

6. Place the lug on the Pilot Control Wire onto the

stud and secure with the nut and washer removed
in the above Step.

7. Tighten the Through-hole Protector onto the Torch

Leads.

8. Check the torch for proper parts assembly.

CAUTION

The torch parts must correspond with the type of
operation. Refer to Section 4.04, Torch Parts Se-
lection.

C. Machine Systems (Shielded Leads)

1. Remove the Through-hole Protector Nut from the

Through-hole Protector.

Through - Hole
Protector Nut

Through - Hole
Protector

Torch Leads
Assembly

Art # A-03849

Figure 3-6 Through-hole Protector Nut Removal

2. The Adapter supplied with the Power Supply must be

installed per the following:

a. Inside the Power Supply Bulkhead area, route the

connector on the free end of the Adapter through
the Through-hole Protector Nut.

b. Continue routing the connector out the hole in the

front of the Power Supply.

c. Feed the end of the torch lead and the Through-

hole Protector into the hole in the unit while rout-
ing the single black wire into the notch of the
Through-hole Protector.

d. Tighten the Through-hole Protector Nut to secure

the Through-hole Protector to the Power Supply.

Advertising
This manual is related to the following products: