APPENDIX

A-4

Manual 0-2818

System

General Purpose
Catalog # 9-8402

MaximumLife

Catalog # 9-8407

CutMaster 75

Optional

Suggested

CutMaster 80XL

Suggested

Optional

CutMaster 100

Optional

Suggested

PakMaster 75XL Plus

Optional

Suggested

PakMaster 100XL Plus

Optional

Suggested

CE PakMaster 75XL Plus

Suggested

Optional

CE PakMaster 100XL Plus

Suggested

Optional

Electrode

APPENDIX 3: GENERAL APPLICATION NOTES

A. Electrode Selection

There are two SureLok

Electrodes, General Purpose and MaximumLife. The information in this section is to help

determine which electrode to use for best performance.

General Purpose SureLok

Electrode (Catalog No. 9-8402)

• General Purpose- Good performance with all systems.

• Design of electrode is similar to previous designed electrodes used in the PCH & M - 60, 75, 76, 80, and 100XL

Torches.

• New patented locking design offers improved parts life, excellent piloting, improved arc transfer distance

and excellent arc characteristics as compared to older electrode designs.

• The General Purpose electrode is the standard electrode offered with SureLok RPT Replacement Torches

providing good all around characteristics and performance.

MaximumLife SureLok Electrode (Catalog No. 9-8407)

• New innovative patented “fluted” design.

• Fluted design optimizes electrode cooling in most applications resulting in a significant improvement in

consumable parts life.

Suggested Applications