Tweco PCM - 102 Machine Torch User Manual

Page 23

Advertising
background image

Manual 0-2818

3-5

INSTALLATION

Adapter

(Supplied With
Power Supply)

Pilot Lead

Torch Lead

Assembly

Negative/Plasma

Lead

Adapter Connector

Pilot Lead

Stud

Negative/Plasma
Lead Connection

A-02829

Control (PIP) Circuit

Connectors

Shield Connectors

Figure 3-7 Shielded Machine Torch Lead Connections

3. Connect the torch Negative & Plasma Lead to the bulk-

head connection inside the Power Supply.

4. Connect the PIP and Shield Cables to the mating con-

nectors on the Adapter supplied on the Power Supply.

5. Remove the top nut and washer from the Pilot Stud.

6. Place the lug on the Pilot Control Wire onto the stud

and secure with the nut and washer removed in the
above Step.

7. Tighten the Through-hole Protector onto the Torch

Leads.

8. Check the torch for proper parts assembly.

CAUTION

The torch parts must correspond with the type of
operation. Refer to Section 4.04, Torch Parts Se-
lection.

D. Remote Pendant Control (Optional)

In machine type operations the Power Supply has an
Adapter that has a cable connector supplied at each
end of the Adapter. One end is connected at the fac-
tory to the mating connector on the Power Supply
Bulkhead area. The other end allows connection of a
Remote Pendant. The remote pendant lead connec-
tor allows connection to a remote pendant or CNC
cable while using PIP connections in the Torch As-
sembly.

Connect the remote pendant control cable to the con-
nector provided on the Adapter from the Power Sup-
ply.

2

3

4

12

14

13

Torch Control

Cable Connector

Remote Pendant/CNC

Cable Connector

PIP

Circuit

Control

OK-To-Move

3

4

12

14

13

A-01366

Figure 3-8 Remote Pendant Connector Diagram

NOTE

Refer to Appendix 2, Torch Control Cable Wiring
Diagram For Mechanized Systems, for detailed
schematic of the Adapter.

Advertising
This manual is related to the following products: