2.05 Input Wiring Specifications
PlazMaster 82 Power Supply Input Cable Wiring Requirements
Input voltage
Freq
Power Input
Suggested Sizes
Volts
Hz
kVA
I max
I
1
eff
Fuse (amps)
Flexible Cord
(Min. AWG)
1 Phase
460
60
20
44
28
50
10
3 Phase
380
50/60
11.8
18
12
20
14
400
50/60
11.8
18
12
20
14
460
60
17
21
14
25
14
Line Voltages with Suggested Circuit Protection and Wire Sizes
Based on National Electric Code and Canadian Electric Code
NOTE
Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.