Plazmaster 82, 01 unpacking, 02 lifting options – Tweco 82 PlazMaster User Manual

Page 23: 03 primary input power connections

Advertising
background image

PLAZMASTER 82

Manual 0-5096

3-1 INSTALLATION

SECTION 3 SYSTEM:

INSTALLATION

3.01 Unpacking

1. Use the packing lists to identify and ac-

count for each item.

2. Inspect each item for possible shipping

damage. If damage is evident, contact

your distributor and / or shipping company

before proceeding with the installation.

3. Record Power Supply and Torch model

and serial numbers, purchase date and ven-

dor name, in the information block at the

front of this manual.

3.02 Lifting Options

The Power Supply includes a handle for hand

lifting only. Be sure unit is lifted and transported

safely and securely.

!

WARNING

Do not touch live electrical parts.
Disconnect input power cord before moving unit.
FALLING EQUIPMENT can cause serious personal

injury and can damage equipment.
HANDLE is not for mechanical lifting.

• Only persons of adequate physical strength

should lift the unit.

• Lift unit by the handles, using two hands.

Do not use straps for lifting.

• Use optional cart or similar device of ad-

equate capacity to move unit.

• Place unit on a proper skid and secure in

place before transporting with a fork lift or

other vehicle.

3.03 Primary Input Power

Connections

CAUTION

Check your power source for correct voltage be-

fore plugging in or connecting the unit. Check the

Voltage Selector at the rear of the unit for correct

setting before plugging in or connecting the unit.

The primary power source, fuse, and any extension

cords used must conform to local electrical code

and the recommended circuit protection and wiring

requirements as specified in Section 2.

Most units are shipped from the factory with a

460Volt input power cable wired to the input

contactor in the single - phase configuration.

The following illustrations and directions are for

changing that configuration to a different voltage

and or to three - phase operation or back again if a

change had already been made.

Art # A-07984_AB

Single-Phase (1ø) and Jumper Settings

L1

L2

L3
L4

Jumper L1 -L4

Jumper

L2-L3

L1
L2
L3

GND

L4

Single Phase Input Power Wiring

Art # A-07983_AB

Three-Phase (3ø) and Jumper Settings

L1

L2

L3
L4

Jumper L1 -L4

L1
L2
L3

GND

L4

Store copper jumper in spare parts box

Three Phase Input Power Wiring

NOTE

There is only one jumper setting that changes

between the single and three phase settings. To

change from single phase to three phase, the

jumper connected to L2 needs to be removed and

placed on the other L3 connection so both ends

of the jumper are attached to the same electrical

point. See previous illustrations.

Advertising