Plazmaster 82 – Tweco 82 PlazMaster User Manual

Page 24

Advertising
background image

PLAZMASTER 82

INSTALLATION 3-2

Manual 0-5096

A. Connections to Single Phase Input Power

WARNING

Disconnect input power from the power supply

and input cable before attempting this procedure.

These instructions are for changing the input

power and or cable on the 400, 460 VAC Power

Supply to Single - Phase input power.

1. Remove the Power Supply cover per in-

structions found in section 5.

2. Disconnect the original input power cable

from the main input contactor and the

chassis ground connection.

3. Loosen the through - hole protector on the

back panel of the power supply. Pull the

original power cable out of the power sup-

ply.

4. If the power cable being used is not the

factory - supplied cable, use a three - con-

ductor input power cable for the voltage

desired and strip back the insulation on the

individual wires.

5. Pass the cable being used through the

access opening in the back panel of the

power supply. Refer to "2.04 Power Sup-

ply Specifications" on page 2-2 for power

cable specifications.

CAUTION

The primary power source and power cable must

conform to local electrical code and the recom-

mended circuit protection and wiring requirements.

6. Connect the wires as follows.

• Set Jumper wires on the contactor. See

previous illustrations.

• Green / Yellow wire to Ground.

• Remaining wires to L1 and L2 input. It

does not matter what order these wires

are attached.

7. With a little slack in the wires, tighten

the through - hole protector to secure the

power cable.

8. Reinstall the Power Supply cover per in-

structions found in section 5.

9. Connect the opposite end of individual

wires to a customer supplied plug or main

disconnect.

10. Connect the input power cable (or close

the main disconnect switch) to supply

power.

B. Connections to Three Phase Input Power

WARNING

Disconnect input power from the power supply

and input cable before attempting this procedure.

These instructions are for changing the input

power and or cable on the 400, 460 VAC Power

Supply to Three - Phase input power.

1. Remove the Power Supply cover per in-

structions found in section 5.

2. Disconnect the original input power cable

from the main input contactor and the

chassis ground connection.

3. Loosen the through - hole protector on the

back panel of the power supply. Pull the

original power cable out of the power sup-

ply.

4. Using a customer supplied four - conductor

input power cable for the voltage desired,

strip back the insulation on the individual

wires.

5. Pass the cable being used through the

access opening in the back panel of the

power supply. Refer to "2.04 Power Sup-

ply Specifications" on page 2-2 for power

cable specifications.

CAUTION

The primary power source and power cable must

conform to local electrical code and the recom-

mended circuit protection and wiring requirements.

6. Connect the wires as follows.

• Set Jumper wires on the contactor. See

illustration.

• Green / Yellow wire to Ground.

• Remaining wires to L1, L2 and L3 in-

put. It does not matter what order these

wires are attached. See the previous

illustrations.

7. With a little slack in the wires, tighten

the through - hole protector to secure the

power cable.

8. Reinstall the Power Supply cover per in-

structions found in section 5.

9. Connect the opposite end of individual

wires to a customer supplied plug or main

disconnect.

10. Connect the input power cable (or close

the main disconnect switch) to supply

power.

Advertising