PLAZMASTER 82

Manual 0-5096

2T-3 INTRODUCTION

B. Gas Distribution

The single gas used is internally split into plasma

and secondary gases.

The plasma gas flows into the torch through the

negative lead, through the starter cartridge, around

the electrode, and out through the tip orifice.

The secondary gas flows down around the outside

of the torch starter cartridge, and out between the

tip and shield cup around the plasma arc.

C. Pilot Arc

When the torch is started a pilot arc is established

between the electrode and cutting tip. This pilot

arc creates a path for the main arc to transfer to the

work.

D. Main Cutting Arc

DC power is also used for the main cutting arc. The

negative output is connected to the torch electrode

through the torch lead. The positive output is con-

nected to the workpiece via the work cable and to

the torch through a pilot wire.

E. Parts - In - Place (PIP)

The torch includes a 'Parts - In - Place' (PIP) circuit.

When the shield cup is properly installed, it closes

a switch. The torch will not operate if this switch

is open.

A-02997

Torch Trigger

PIP Switch

Shield Cup

To Control

Cable Wiring

Torch Switch

Parts - In - Place Circuit Diagram for Hand Torch

PIP Switch

Shield Cup

To ATC

CNC Start

PIP Switch

Shield Cup

PIP Switch

Shield Cup

Remote Pendant

Automation Torch

To ATC

To ATC

Art # A-08168

Parts - In - Place Circuit Diagram for Machine Torch