3-3 INSTALLATION

3.04 Gas Connections

Connecting Gas Supply to Unit

The connection is the same for compressed air or

high pressure cylinders. Refer to the following

two subsections if an optional air line filter is to

be installed.

1. Connect the air line to the inlet port. The

illustration shows typical fittings as an

example.

NOTE

For a secure seal, apply thread sealant to the fitting

threads, according to manufacturer's instructions.

Do not use Teflon tape as a thread sealer, as small

particles of the tape may break off and block the

small air passages in the torch.

Art # A-07943

Hose Clamp

Regulator/Filter

Assembly

Inlet Port

Gas Supply

Hose

1/4 NPT or ISO-R

to 1/4” (6mm) Fitting

Air Connection to Inlet Port

Installing Optional Single - Stage Air Filter

An optional filter kit is recommended for im-

proved filtering with compressed air, to keep

moisture and debris out of the torch.

1. Attach the Single - Stage Filter Hose to the

Inlet Port.

2. Attach the Filter Assembly to the filter

hose.

3. Connect the air line to the Filter. The

illustration shows typical fittings as an

example.

NOTE

For a secure seal, apply thread sealant to the fitting

threads, according to the maker's instructions. Do

Not use Teflon tape as a thread sealer, as small

particles of the tape may break off and block the

small air passages in the torch. Connect as follows:

Art # A-07944

Hose Clamp

1/4 NPT to 1/4"

(6mm) Fitting

Regulator/Filter

Assembly

Inlet Port

Gas Supply

Hose

Optional Single - Stage Filter Installation

Installing Optional Two - Stage Air Filter Kit

This optional two - stage air line filter is also

for use on compressed air shop systems. Filter

removes moisture and contaminants to at least 5

microns.

Connect the air supply as follows:

1. Attach the Two Stage Filter bracket to the

back of the power supply per instructions

supplied with the filter assembly.

NOTE

For a secure seal, apply thread sealant to the fitting

threads according to manufacturer's instructions.

Do Not use Teflon tape as a thread sealer as small

particles of the tape may break off and block the

small air passages in the torch.

2. Connect the two stage filter outlet hose to

the inlet port of the Regulator / Filter As-

sembly.

3. Use customer - supplied fittings to connect

the air line to the Filter. A 1/4 NPT to 1/4"

hose barbed fitting is shown as an example.

Advertising