Ultra-cut 400, 04 lift the power supply – Tweco 400 Ultra-Cut User Manual
Page 30

INSTALLATION
3-4
Manual No. 0-5164
ULTRA-CUT 400
3.04 Lift the Power Supply
WARNINGS
Do not touch live electrical parts.
Disconnect input power conductors from de-energized supply line before moving unit.
FALLING EQUIPMENT can cause serious personal injury and equipment damage.
Use all four lifting eyes when using lifting straps to lift the power supply.
Use a forklift, crane, or hoist to lift the unit off the shipping pallet as shown. Keep the power supply steady and verti-
cal. Do not lift it any further than necessary to clear the shipping pallet. Ensure all panels and screws are secure
prior to lifting.
Art # A-04796
Set the power supply on a solid, level surface. The installer may fasten the power supply to the floor or a support-
ing fixture with hardware passing through the horizontal parts of the power supply feet.