Ultra-cut 400 – Tweco 400 Ultra-Cut User Manual
Page 85

Manual No. 0-5164
4-11 OPERATION
ULTRA-CUT 400
B. Shield Gases
1. Compressed Air Shield
• Air shield is normally used when operating with air plasma.
• Improves cut quality on some ferrous materials.
• Inexpensive - reduces operating costs.
2. Nitrogen (N2) Shield
• Nitrogen shield is used with Ar/H2
(H35) plasma.
• Provides smooth finishes on nonferrous materials.
• May reduce smoke when used with Ar/H2 plasma.
3. Water Shield
• Water shield should be used only in mechanized applications - never in hand cutting!
• Normally used with nitrogen, Ar/H2, or air plasma.
• Provides very smooth cut surface.
• Reduces smoke and heat input to the workpiece.
• Effective up to 1/2 inch (12.7 mm) maximum material thickness.
• Tap water provides low operating expense.