Ultra-cut 400 – Tweco 400 Ultra-Cut User Manual
Page 45

Manual No. 0-5164
3-19 INSTALLATION
ULTRA-CUT 400
3.11 Connect Fiber Optic Cable (Type 3 internal control module)
CAUTION
Check the type of internal control module.
1. Connect one end of each cable to the power supply as shown.
a. Remove the strain relief securing nut from the strain relief on the fiber optic cable(s). Loosen the strain
relief dome nut from the strain relief.
b. Pass the cable connector through the appropriate opening. Slide the strain relief securing nut onto the
cable. Make a loop of the cable; carefully press the cable connector into the appropriate receptacle on
the internal control module.
c. Tighten the strain relief onto the cable(s). Do not overtighten.
Thin nut securing
the through hole
protector
Fiber Optic
Cable
Plug
Art # A-09456