Cutmaster 10mm, 12mm, 06 input wiring specifications – Tweco 12mm Cutmaster User Manual

Page 16

Advertising
background image

CUTMASTER 10MM, 12MM

SYSTEM INTRODUCTION 2-4 Manual 0-5197AD

2.06 Input Wiring Specifications

CUTMASTER 10mm Input Power Requirements

Input

Power Input

Current Input

Current Input

Suggested Sizes (See Note)

Voltage

Frequency

(kVA)

Max (Amps)

I

1

eff (Amps)

Fuse (Amps)

(Volts-AC)

(Hz)

1-Ph

1-Ph

1-Ph

1-Ph

240

50/60

3.8

15.6

9.9

16

Line Voltages with Suggested Circuit Protection
Motor start fuses or thermal circuit breakers are recommended for this application. Check local requirements for your

situation in this regard.

CUTMASTER 12mm Input Power Requirements

Input

Power Input

Current Input

Current Input

Suggested Sizes (See Note)

Voltage

Frequency

(kVA)

Max (Amps)

I

1

eff (Amps)

Fuse (Amps)

(Volts-AC)

(Hz)

1-Ph

1-Ph

1-Ph

1-Ph

240

50/60

5.0

20.8

13

16

Line Voltages with Suggested Circuit Protection
Motor start fuses or thermal circuit breakers are recommended for this application. Check local requirements for your

situation in this regard.

NOTE

Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.

Cable size is de-rated based on the Duty Cycle of the equipment.
The suggested sizes are based on flexible power cable with power plug installations.
Cable conductor temperature used is 167° F (75° C).

Advertising