Cutmaster 10mm, 12mm – Tweco 12mm Cutmaster User Manual

Page 38

Advertising
background image

CUTMASTER 10MM, 12MM

TORCH SERVICE 5T-2 Manual 0-5197AC

5T.02 Inspection and Replacement of

Consumable Torch Parts

WARNING

Disconnect primary power to the system

before disassembling the torch or torch leads.
DO NOT touch any internal torch parts while

the AC indicator light of the Power Source is

ON.

Remove the consumable torch parts as follows:

NOTE

The shield cup holds the tip and starter car-

tridge shield cup in place. Position the torch

with the shield cup facing upward to prevent

these parts from falling out when the cup is

removed.

1. Unscrew and remove the shield cup from the

torch.

NOTE

Slag built up on the shield cup that cannot

be removed may effect the performance of

the system.

2. Inspect the cup for damage. Wipe it clean or

replace if damaged.

Art# A-09345

Electrode

Start Cartridge

Tip

Shield Cup

Torch Head

Figure 5-3 - Consumable Parts

3. Remove the tip. Check for excessive wear (indi-

cated by an elongated or oversized orifice). Clean

or replace the tip if necessary.

Good Tip

Worn Tip

A-09791

Figure 5-4 - Tip Wear

4. Remove the starter cartridge. Check for excessive

wear, plugged gas holes, or discoloration. Check

the lower end fitting for free motion. Replace if

necessary.

Art A-09792

Figure 5-5 - Start Cartridge

5. Pull the electrode straight out of the torch head.

Check the face of the electrode for excessive wear.

Refer to Figure 5-6.

Worn Electrode

New Electrode

Art # A-03284

Figure 5-6 - Electrode Wear

6

. Reinstall the electrode by pushing it straight into

the torch head until it clicks.

7

. Reinstall the desired starter cartridge and tip into

the torch head.

8. Hand tighten the shield cup until it is seated on the

torch head. If resistance is felt when installing the

cup, check the threads before proceeding.

Advertising