2.05 Input Wiring Specifications

CutMaster 82 Power Supply Input Cable Wiring Requirements

Input voltage

Freq

Power Input

Suggested Sizes

Volts

Hz

kVA

I max

I

1

eff

Fuse (amps)

Flexible Cord

(Min. AWG)

1 Phase

208

60

16

75

48

100

6

230

60

17

72

46

100

6

460

60

20

44

28

50

10

3 Phase

208

60

16

40

26

50

8

230

50/60

16

39

25

50

10

380

50/60

11.8

18

12

20

12

400

50/60

11.8

18

12

20

12

460

60

17

21

14

25

12

600

60

9.6

16

10

20

12

Line Voltages with Suggested Circuit Protection and Wire Sizes

Based on National Electric Code and Canadian Electric Code

NOTE

Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.
Cable size is de-rated based on the Duty Cycle of the equipment.