CUTMASTER 82

INSTALLATION

Manual 0-4979

3-2

NOTE

There is only one jumper setting that changes

between the single and three phase settings.

To change from single phase to three phase,

the jumper connected to L2 needs to be

removed and placed on the other L3 connec-

tion so both ends of the jumper are attached

to the same electrical point. See previous

illustrations.

A. Connections to Single Phase Input Power

WARNING

Disconnect input power from the power

supply and input cable before attempting

this procedure.

These instructions are for changing the input power and

or cable on the 208/230, 400, 460 VAC Power Supply to

Single - Phase input power.

1. Remove the Power Supply cover per instructions

found in section 5.

2. Disconnect the original input power cable from

the main input contactor and the chassis ground

connection.

3. Loosen the through - hole protector on the back

panel of the power supply. Pull the original

power cable out of the power supply.

4. If the power cable being used is not the factory

- supplied cable, use a three - conductor input

power cable for the voltage desired and strip

back the insulation on the individual wires.

5. Pass the cable being used through the access

opening in the back panel of the power supply.

Refer to Section 2 for power cable specifications.

CAUTION

The primary power source and power cable

must conform to local electrical code and the

recommended circuit protection and wiring

requirements (refer to table in Section 2).

6. Connect the wires as follows.

• Set Jumper wires on the contactor. See previ-

ous illustrations.

• Green / Yellow wire to Ground.

• Remaining wires to L1 and L2 input. It does

not matter what order these wires are at-

tached.

7. With a little slack in the wires, tighten the through

- hole protector to secure the power cable.

8. Reinstall the Power Supply cover per instructions

found in section 5.

9. Connect the opposite end of individual wires to

a customer supplied plug or main disconnect.

10. Connect the input power cable (or close the main

disconnect switch) to supply power.

B. Connections to Three Phase Input Power

WARNING

Disconnect input power from the power

supply and input cable before attempting

this procedure.

These instructions are for changing the input power and

or cable on the 208/230, 400, 460 VAC Power Supply to

Three - Phase input power.

1. Remove the Power Supply cover per instructions

found in section 5.

2. Disconnect the original input power cable from

the main input contactor and the chassis ground

connection.

3. Loosen the through - hole protector on the back

panel of the power supply. Pull the original

power cable out of the power supply.

4. Using a customer supplied four - conductor input

power cable for the voltage desired, strip back

the insulation on the individual wires.

5. Pass the cable being used through the access

opening in the back panel of the power supply.

Refer to Section 2 for power cable specifications.

CAUTION

The primary power source and power cable

must conform to local electrical code and the

recommended circuit protection and wiring

requirements (refer to table in Section 2).

6. Connect the wires as follows.

• Set Jumper wires on the contactor. See illus-

tration.

• Green / Yellow wire to Ground.

• Remaining wires to L1, L2 and L3 input. It

does not matter what order these wires are

attached. See the previous illustrations.