Cutmaster 82 – Tweco 82 CutMaster User Manual

Page 58

Advertising
background image

CUTMASTER 82

SERVICE

Manual 0-4979

5-8

!

WARNING

Always turn OFF the air supply and bleed

the system before disassembling the Filter

Assembly as injury could result.

3. Loosen the two bolts on the top of the Filter As-

sembly enough to allow the Filter Elements to

move freely.

4. Note the location and orientation of the old Filter

Elements.

5. Slide out the old Filter Elements.

First & Second

Stage

Cartridges

(as marked)

Art # A-02942

Optional Two-Stage Filter Replacement

6. Slide the replacement Filter Elements into the

Filter Assembly, with the same orientation as

noted in Step 4 above.

7. Hand tighten the two bolts evenly, then torque

each bolt to 20 - 30 in-lbs (2.3 - 3.4 Nm). Improper

torque may damage the gasket.

8. Slowly apply air pressure to the assembly, check-

ing for leaks.

NOTE

A small amount of air leakage from the bot-

tom fitting is normal.

This completes the parts replacement procedures.