5.04 Fault Indicator

At initial power up, two lights will temporarily illumi-

nate for 2-3 seconds to show the version of software used.

To determine the first digit, count the function indicators

left to right, 1 through 5. To determine the second digit

count the pressure indicators, reading from bottom to

top, 0 through 7. In the example below the Temp indica-

tor and 75 psi indicators are ON indicating the version

would be 2.3.

A

+

PSI

BAR

MAX

MAX

MIN

MIN

!

1 2 3 4

Art# A-07988

MIN

MAX

0

1

2

3

4

5

6

7

5

When the

!

"Fault" indicator is ON or blinking it

will be accompanied by one of the pressure indicator

lights depending on what the Fault is. The following

table explains each of those Faults.

Pressure

Indicator

Fault

Max

Over Pressure

90

Internal Error

85

Shorted Torch

80

Consumables Missing

75

Start Error

70

Parts in Place

65

Input Power

Min

Under Pressure

NOTE

Fault explanations are covered in the follow-

ing tables.