10 specifications, 10 specifications -5, Transarc 130i – Tweco 130i Transarc Operating Manual User Manual

Page 17

Advertising
background image

TRANSARC 130i

Manual 0-5283

2-5

INTRODUCTION

2.10 Specifications

Description

Transarc 130i

Plant Part No
Plant Part No (Mine Spec)
Power Source Part No (Mine Spec)

W1007130
W1007131
W1007129

Power Source Dimensions

H306mmxW121mmxD376mm

Power Source Mass

7 KG

Cooling

Fan Cooled

Welder Type

Multi Process Inverter Power Source

Australian Standard

AS 60974.1-2006 / IEC 60974.1

Number of Phases

Single Phase

Nominal Supply Voltage

240V ± 15%

Nominal Supply Frequency

50/60Hz

Welding Current Range

5-130A

Nominal DC Open Circuit Voltage (VRD ON)

8V

Nominal DC Open Circuit Voltage (VRD OFF)

66V

Factory Fitted Supply Plug Rating

10 Amps

Effective Input Current (I

1eff

) refer Note 2

9 Amps

Maximum Input Current (I

1max

)

17 Amps

Minimum Single Phase Generator

Recommendation (refer Note 4)

4.8k W (6.2k VA at 0.8 PF)

STICK (MMAW) Welding Output, 40ºC, 10 min.

130A @ 25%, 25.2V

80A @ 60%, 23.2V

60A @ 100%, 22.4V

TIG (GTAW) Welding Output, 40ºC, 10 min.

130A @ 25%, 15.2V

80A @ 60%, 13.2V

60A @ 100%, 12.4V

Protection Class

IP23S

Table 2-1: Transarc 130i Specifications

NOTE 1

Due to variations that can occur in manufactured products, claimed performance, voltages, ratings,

all capacities, measurements, dimensions and weights quoted are approximate only. Achievable

capacities and ratings in use and operation will depend upon correct installation, use, applications,

maintenance and service.

NOTE 2

The Effective Input Current should be used for the determination of cable size & supply requirements.

NOTE 3

Motor start fuses or thermal circuit breakers are recommended for this application. Check local

requirements for your situation in this regard.

Advertising