Transarc 130i – Tweco 130i Transarc Operating Manual User Manual

Page 24

Advertising
background image

TRANSARC 130i

INSTALLATION, OPERATION AND SETUP

3-6

Manual 0-5283

Programming Parameter

Control Panel Display

Arc Force

Arc Force is effective when in

STICK mode only. Arc Force control

provides an adjustable amount of

Arc Force (or "dig") control. This

feature can be particularly beneficial

in providing the operator the ability

to compensate for variability in

joint fit-up in certain situations with

particular electrodes. In general

increasing the Arc Force control

toward 100% (maximum Arc

Force) allows greater penetration

control to be achieved.
Range is 0 to 100%. Factory default

is 30%.

LIFT TIG Programming Mode

Programming Parameter

Control Panel Display

Initial Current

This parameter operates in TIG

mode only and is used to set the

start current for TIG. In 4T mode

the Initial Current remains on until

the torch trigger switch is released

after it has been depressed. In 2T

mode this is the Initial Current for

the Up Slope current ramp.
Range is 5 to 130A. Factory default

is 30A.

Up Slope

This parameter operates in TIG

mode only and is used to set the

time for the weld current to ramp

up from INITIAL current to BASE

current.
Range is 0.0 to 15.0 seconds.

Factory default is 1.0 second.