TRANSARC 130i

INSTALLATION, OPERATION AND SETUP

3-18

Manual 0-5283

3.10 Setup for Manual Arc (MMAW) Welding

A. Connect the Electrode Holder lead to the positive welding terminal (+). If in doubt, consult the electrode

manufacturer. Welding current flows from the Power Source via heavy duty bayonet type terminals. It is

essential, however, that the male plug is inserted and turned securely to achieve a sound electrical connection.

B. Connect the work lead to the negative welding terminal (-). If in doubt, consult the electrode manufacturer.

Welding current flows from the power source via heavy duty bayonet type terminals. It is essential, however,

that the male plug is inserted and turned securely to achieve a sound electrical connection.

!

WARNING

Before connecting the work clamp to the work and inserting the electrode in the electrode holder

make sure the mains power supply is switched off.

CAUTION

Remove any packaging material prior to use. Do not block the air vents at the front or rear of the

Welding Power Source.
Loose welding terminal connections can cause overheating and result in the male plug being

fused.

Figure 3-10: Setup for Manual Arc Welding