TRANSARC 130i

Manual 0-5283

3-7

INSTALLATION, OPERATION AND SETUP

Base Current

This parameter sets the TIG welding

current.
Range is 5 to 130A. Factory default

is 120A.

Down Slope

This parameter operates in TIG

mode only and is used to set

the time for the weld current to

ramp down to the crater current.

This control is used to eliminate

the crater that can form at the

completion of a weld.
Range is 0.0 to 25.0 seconds.

Factory default is 3.0 seconds.

Crater Current

This parameter operates in TIG

mode only.
In 2T mode this is the current at

the end of the down slope current

ramp. When the welding current

reaches the Crater Current value,

the welding current will cease and

the unit will enter Post Flow mode.
In 4T mode, this is the current at

the end of the down slope current

ramp. The welding current will

remain at the Crater Current value

until the torch trigger is released, at

which time the welding current will

cease and the unit will enter Post

Flow mode.
Range is 5 to 130A. Factory default

is 30A.