INSTALLATION, OPERATION AND SETUP

A-11745

There will be 0V on the Power Source welding terminals and both VRD lights will be off.

In both 2T and 4T modes, if the stick electrode is not touched to the work piece within three seconds,

the welding output will be inhibited. Release the trigger to reset, and press the trigger again to reactivate

the VRD.

Note that if the Dead Man Switch function is disabled, 2T and 4T are not available in STICK mode.

Information on how to disable the Dead Man Switch function is available from Cigweld Technical Customer

Care on +61 3 9474 7400

!

WARNING

Approval from a mine site manager, or work site manager must be obtained in writing before the

Dead Man Switch function is disabled. Only a suitably qualified electrical tradesperson or Cigweld

Service Provider should make any changes to the Power Source.

!

WARNING

The Power Source must be turned off and unplugged from the mains supply before the Dead Man

Switch function is changed.

!

WARNING

If 4T operation is selected when using the Dead Man Switch mode, the use of an observer is

recommended.