2.08 WeldSkill 250 MIG Power Source Specifications

Identification, Weights & Measures

WeldSkill 250

Plant Assembly

W003400

Plant Dimensions

(including cylinder carrier & wheels)

H 980mm x W 440mm x D 988mm

Power Source Part Number

W00340

Power Source Mass

00 kg

Energy Input (Refer NOTE Below)

This Column Applies to the

Factory Fitted 2.5mm

2

(20A)

Primary Lead

This Column Applies to a

4.0mm

2

(25A) Primary Lead

Input Cable Requirements

2.5mm

2

2 core + earth heavy

duty R90 insulation type.

4.0mm

2

2 core + earth heavy

duty R90 insulation type

Supply Input Voltage

240 VAC

240 VAC

Number of Phases & Frequency

Single Phase 50 Hz

Single Phase 50 Hz

Rated Input Current @ 00% Duty Cycle

♥9.5 A

♥27 A

Rated kVA @ 00% Duty Cycle

4.7 kVA

6.5 kVA

Maximum Input Current

43 A

54 A

Generator Requirements

♣5 kVA

♣5 kVA

Supply VA @ no load

480 VA

480 VA

Supply VA @ max. output

0.3 kVA

3 kVA

Rated Outlet Maximum Duty Cycle

20 A

30 A

Recommended Fuse Size

♠45 A

♠60 A

Welding Output (Refer NOTE Below)

This Column Applies to the

Factory Fitted 2.5mm

2

(20A)

Primary Lead

This Column Applies to a

4.0mm

2

(27A) Primary Lead

Open Circuit Voltage Range

22 to 46 V

22 to 46 V

Output Current Range

50 – 230 A

50 – 270 A

Rated Output Duty Cycle

230 A@ 20%

250 A@ 20%

00% Duty Cycle Output Rating

07 A

30 A

Operating Temperature Range

0ºC - 40ºC

0ºC - 40ºC

Duty Cycle Period

0 minutes

0 minutes

Number of Output Voltage Switch Settings

2

Maximum Inlet Gas Pressure

.2 MPa (gas hose)

Suitable Gas Types

Argon based mixed gases & C0

2

Wire Size Range Hard Wire:

Fluxcored Wire:

0.6mm – .0mm

.0mm – .2mm

Table 2- WeldSkill 250 Power Source Specifications

♥ The Rated Input Current should be used for the determination of cable size & supply requirements.

♠ Motor start fuses or thermal circuit breakers are recommended for this application. Check local

requirements for your situation in this regard.

♣ Generator Requirements at the Maximum Output Duty Cycle.
♦ Reduced output ratings apply with the supplied 20A primary lead. To achieve the maximum rated

output & duty cycle ratings the 20A primary lead must be replaced with a larger primary lead as

specified in section 3.04. This must be carried out be a qualified electrical tradesperson.