Tweco 250 Weldskill MIG User Manual

Page 32

Advertising
background image

6-2

Manual No 0-5072

weldskill 250, 350 operation

December , 2008

4. COARSE VOLTAGE CONTROL SWITCH (WELDSKILL 350 ONLY)

The Coarse Voltage Control increases the voltage (in larger increments than the Fine switch) as it is rotated

in the clockwise direction.

CAUTION

The Coarse & Fine Voltage Control switches MUST NOT BE SWITCHED during the welding pro-

cess.

5. TORCH POLARITY LEAD

This lead selects the welding voltage polarity of the electrode wire. Plug it into the positive welding terminal

(+) when using steel, stainless steel or aluminium electrode wire. Plug the Torch Polarity Lead into the

negative welding terminal (-) when using gasless electrode wire. If in doubt, consult the manufacturer of
the electrode wire for the correct polarity.

6. POSITIVE WELDING TERMINAL

Positive Welding Terminal. Welding current flows from the Power Source via heavy duty bayonet type

terminals. It is essential, however, that the male plug is inserted and turned securely to achieve a sound

electrical connection.

7. NEGATIVE WELDING TERMINAL

Negative Welding Terminal. Welding current flows from the Power Source via heavy duty bayonet type

terminals. It is essential, however, that the male plug is inserted and turned securely to achieve a sound

electrical connection.

CAUTION

Loose welding terminal connections can cause overheating and result in the male plug being fused

in the terminal.

8. TORCH CONNECTOR

The MIG torch connects to this outlet.

9. OVERHEAT INDICATOR

The critical component for thermal protection is the rectifier stack, which is fitted with a thermal overload cut

out device. If the overload operates then the machine should be left to cool for approximately 5 minutes

before resuming welding. The thermal overload will not operate and there will be no danger of transformer

damage if the Power Source is operated within its duty cycle.
The WeldSkill 250 and 350 Compact Power Source has a front panel indication of Overheat (Thermal

Overload).

10. VOLTAGE CONTROL SWITCH MODE SWITCH (WELDSKILL 250 ONLY)

The Voltage Control Switch increases the voltage as it is rotated in the clockwise direction. And do not

switch it while welding is going on.