INSTALLATION/SETUP

TRANSMIG 250i

Manual 0-5187

3-5 INSTALLATION/SETUP

+

-

11

12

13

14

15

Art # A-10319

16

Figure 3-2: Transmig Front Connections

WARNING

DO NOT TOUCH the electrode wire while it is

being fed through the system. The electrode

wire will be at welding voltage potential.

1. VRD Indicator

ON

OFF

A VRD (voltage reduction device) is designed to reduce

electric shock hazards present on the output of welding

power source when operating in STICK mode. Note that

the presence of VRD should not be used as a substitute

for the use of appropriate safety practices as indicated in

section one of this manual.
Both the green and red indicator lights only operate in

STICK mode.
The green VRD ON light illuminates (red light is OFF)

when the VRD is active. Under this condition the open

circuit voltage of the unit is limited to below 35V DC, thus

reducing the potential of serious electric shock (such as

when changing electrodes).
The red VRD OFF light illuminates (green light is OFF)

when the VRD is inactive. Under this condition the output

voltage of the unit will be at welding potential which in

some cases may exceed 35V DC.

WARNING

When the red VRD indicator is on and welding

is being performed, the presence of dangerous

voltage may be present at the electrode.

2. Power Indicator

The green power indicator will be illuminated when the

welder is turned ON and indicates the presence of power.
3. Fault Indicator

The yellow fault indicator will be illuminated when any

of the faults are detected. ALL Faults will illuminate the

indicator
4. Weld Process Selection Button

LIFT TIG

Press and release this button to change the selected weld

process mode from MIG to LIFT TIG to STICK. The weld

process will change to the next process in the sequence

each time the button is pressed and released. The red

indicators next to the button will illuminate to identify MIG

or LIFT TIG or STICK process mode.

.

WARNING

When the Power light is lit, the machine is

connected to the Mains supply voltage and

the internal electrical components are at Mains

voltage potential.

5. 2T - 4T Trigger Latch Button

Press and release the button to change the selected op-

erating mode of the trigger. The selected mode can be

either “2T” (unlatched) or “4T” (latched) operation. The

red indicator next to the button will illuminate to identify

which mode is selected (2T or 4T). In the 4T mode once

the weld has been started you can release the trigger and

continue welding until the trigger is activated again or the

welding arc is broken to stop the welding arc.