Transmig 250i installation/setup – Tweco 250i Transmig Inverter User Manual

Page 52

Advertising
background image

TRANSMIG 250i

INSTALLATION/SETUP

INSTALLATION/SETUP 3-34

Manual 0-5187

1. Turn the Main ON/OFF switch OFF (located on the rear panel).
2. Check that the MIG wire size, contact tip, MIG Torch liner and drive roll groove are all the same size before

fitting the MIG wire into the Power Source.

3. Connect the MIG Torch Polarity Lead to the negative welding terminal (-). If in doubt, consult the MIG electrode

wire manufacturer. Welding current flows from the Power Source via heavy duty bayonet type terminals. It is

essential, however, that the male plug is inserted and turned securely to achieve a sound electrical connection.

4. Fit the MIG (FCAW) wire spool and MIG Torch to the Power Source. (Refer to section 3.13 to 3.21 ).
5. Connect the work lead to the positive welding terminal (+). If in doubt, consult the MIG electrode wire manu-

facturer. Welding current flows from the Power Source via heavy duty bayonet type terminals. It is essential,

however, that the male plug is inserted and turned securely to achieve a sound electrical connection.

6. If gasless MIG (FCAW) wire is fitted then shielding gas is not required for welding. Otherwise fit the welding

grade shielding gas regulator/flow gauge to the shielding gas cylinder (refer to Section 3.22) then connect the

shielding gas hose from the rear of the power source to the regulator/flow gauge outlet.

7. Turn the Main ON/OFF switch ON (located on the rear panel).
8. Select MIG mode with the process selection control. (Refer to Section 3.06.4 for further information)
9. Remove the MIG Torch nozzle and contact tip.
10. Depress MIG Torch trigger to feed the MIG wire out through the MIG Torch gas diffuser then fit the contact

tip on the MIG wire and securely fasten it to the MIG Torch then Fit the nozzle in place.

11. Refer to the Weld Guide located on the inside of the wire feed compartment door for further information on

Voltage/Wirespeed settings.

WARNING

Before connecting the work clamp to the work make sure the mains power supply is switched OFF.

CAUTION

Loose welding terminal connections can cause overheating and result in the male plug being fused in the

terminal.
Remove any packaging material prior to use. DO NOT block the air vents at the front or rear of the Welding

Power Source.

NOTE

Depending on the type of wire you will be using the MIG Torch polarity may need to be switched. Follow

the wire manufacturers recommendation.

Advertising