05 high frequency introduction, 06 high frequency interference, Transmig 400 i – Tweco 400i Transmig User Manual

Page 21

Advertising
background image

TRANSMIG 400 i

July 18, 2008

3-3

3.05 High Frequency Introduction

The importance of correct installation of high
frequency welding equipment cannot be
overemphasized. Interference due to high frequency
initiated or stabilized arc is almost invariably traced
to improper installation. The following information is
intended as a guide for personnel installing high
frequency welding machines.

!

WARNING: EXPLOSIVES

The high frequency section of this machine
has an output similar to a radio transmitter.
The machine should NOT be used in the
vicinity of blasting operations due to the
danger of premature firing.

!

WARNING: COMPUTERS

It is also possible that operation close to
computer installations may cause
computer malfunction.

3.06 High Frequency Interference

Interference may be transmitted by a high frequency
initiated or stabilized arc welding machine in the
following ways:

1. Direct Radiation: Radiation from the machine can

occur if the case is metal and is not properly
grounded. It can occur through apertures such
as open access panels. The shielding of the high
frequency unit in the Power Source will prevent
direct radiation if the equipment is properly
grounded.

2. Transmission via the Supply Lead: Without

adequate shielding and filtering, high frequency
energy may be fed to the wiring within the
installation (mains) by direct coupling. The energy
is then transmitted by both radiation and
conduction. Adequate shielding and filtering is
provided in the Power Source.

3. Radiation from Welding Leads: Radiated

interference from welding leads, although
pronounced in the vicinity of the leads, diminishes
rapidly with distance. Keeping leads as short as
possible will minimize this type of interference.
Looping and suspending of leads should be
avoided where possible.

4. Re-radiation from Unearthed Metallic Objects:

A major factor contributing to interference is re-
radiation from unearthed metallic objects close
to the welding leads. Effective grounding of such
objects will prevent re-radiation in most cases.

Advertising