4 guide for selecting filler wire diameter, 5 shielding gas selection, Transmig 400 i – Tweco 400i Transmig User Manual

Page 36

Advertising
background image

TRANSMIG 400 i

5-2

July 18, 2008

5.01.4 Guide for Selecting Filler Wire Diameter

Filler Wire Diameter

AC Current Range

(Amps)

DC Current Range

(Amps)

1/16” (1.6 mm)

30 - 95

20 - 90

3/32” (2.4 mm)

125 - 160

65 - 115

1/8” (3.2 mm)

180 - 240

100 - 165

3/16” (4.8 mm)

220 - 320

200 - 350

NOTE 1

The filler wire diameter specified in the above table is a guide only, other diameter wires may be
used according to the welding application.

5.01.5 Shielding Gas Selection

Alloy Shielding

Gas

Aluminum & alloys

Welding Argon

Carbon Steel

Welding Argon

Stainless Steel

Welding Argon

Copper Welding

Argon

5.01.6 TIG Welding Parameters for Low Carbon & Low Alloy Steel Pipe

Electrode Type &

Diameter

Current Range DC

Amperes

Filler Rod for

Root Pass

Joint Preparation

Thoriated 2%

3/32” (2.4 mm)

120 - 170

Yes

Thoriated 2%

3/32” (2.4 mm)

100 - 160

Yes

Thoriated 2%

3/32” (2.4 mm)

90 - 130

No

Advertising