6.10 Voltage Reduction Device (VRD)

1. VRD Specification:

Description

Transtig 400 i

Notes

VRD Open Circuit Voltage 15.3 to 19.8V

Open circuit voltage between welding
terminals

VRD Resistance

148 to 193 ohms The required resistance between welding

terminals to turn ON the welding power

VRD Turn OFF Time

0.2 to 0.3 seconds The time taken to turn OFF the welding

power once the welding current has
stopped

2. VRD Maintenance:

Routine inspection and testing (power source):

An inspection of the power source, an insulation resistance test and an earth resistance test shall be carried
out.

a) For transportable equipment, at least once every 3 months; and

b) For fixed equipment, at least once every 12 months.

The owners of the equipment shall keep a suitable record of the periodic tests.

NOTE

A transportable power source is any equipment that is not permanently connected and fixed in the
position in which it is operated.

In addition to the above tests and specifically in relation to the VRD fitted to this machine, the following
periodic tests should also be conducted by an accredited Cigweld service agent.

Description

Required Parameters

VRD Open Circuit

Voltage

Less than 20V; at Vin=415V

VRD Turn ON

Resistance

Less than 200 ohms

VRD Turn OFF

Time

Less than 0.3 seconds

Periodic Tests

If this equipment is used in a hazardous location or environments with a high risk of electrocution then the
above tests should be carried out prior to entering this location.