TRANSMIG 2RT

INSTALLATION/SETUP

INSTALLATION/SETUP 3-6

Manual 0-5196

CONTINUATION OF 250I POWER SOURCE CONTROLS

1. VRD Indicator

ON

OFF

WARNING

When the red VRD indicator is on and welding

is being performed, the presence of dangerous

voltage may be present at the electrode.

2. Power Indicator

The green power indicator will be illuminated when the

welder is turned on and indicates the presence of power.
3. Fault Indicator

The yellow fault indicator will be illuminated when any

of the faults are detected. ALL Faults will illuminate the

indicator
4. Weld Process Selection Button

LIFT TIG

WARNING

When the Power light is lit, the machine is

connected to the Mains supply voltage and

the internal electrical components are at Mains

voltage potential.

5. 2T - 4T Trigger Latch Button

6. Advanced Features Button

Gas Purge.

7. Left Knob: Amperage Control (Wirespeed)

Left Knob

8. Right Knob: Multifunction Control - MIG Voltage /

MIG Voltage Control

Right Knob

Push For Inductance

Arc Control

9. Left Digital Display

MIG Mode
This digital meter is used to display the pre-set (preview)

Wirefeed Speed in Metres Per Minute (MPM) in MIG mode

and actual welding amperage of the power source when