Installation/setup transmig 2rt – Tweco 2RT Transmig User Manual

Page 25

Advertising
background image

INSTALLATION/SETUP

TRANSMIG 2RT

Manual 0-5196

3-9 INSTALLATION/SETUP

3.10 Wire Feeder Set-up for MIG (FCAW) Welding with Gasless MIG Wire

The Transmig 250i is supplied with a Tweco Fusion 250 AMP air-cooled MIG Torch that can be used with the 2RT Wire

Feeder. The Fusion MIG Torch is designed with an ergonomic handle and fewer parts to cause performance problems.

The Fusion MIG Torch uses standard readily available Tweco Fusion consumable parts.
When using a gasless flux cored wire, you do not need to have an external gas source attached to the 2RT Wire Feeder.

If one is, then make sure it is turned off.
For most Self Shielded Flux Cored Wire, connect the Work Lead to the positive + terminal on the front of the 250i

and connect the Welding Power Cable from the back of the 2RT to the negative - terminal on the front of the 250i.
The 2RT Wire Feeder is fitted with an 8M interconnection cable assembly to connect from the back of the 2RT to the

front of the 250i welding power source. See Figure 3-7 below.

+

-

Front View 2RT

Rear View 2RT

Front View 250i

Control Cable

Welding Power Cable

from Wire Feeder

Work Lead

Art # 10350_AB

Figure 3-7: Setup for 2RT Wirefeeder with Gasless MIG Wire

WARNING

Before connecting the work clamp to the work make sure the mains power supply is switched off.

CAUTION

Loose welding terminal connections can cause overheating and result in the male plug being fused in the

terminal.
Remove any packaging material prior to use. Do not block the air vents at the front or rear of the Welding

Power Source.

NOTE

Depending on the type of wire you will be using the MIG Torch polarity may need to be switched. Follow

the wire manufacturers recommendation.

NOTE

Spool hub and feed plate set up and operation are the same as the 250i which can be reviewed later in this

section starting at 3.12.

Advertising