INSTALLATION/SETUP

TRANSMIG 2RT

Manual 0-5196

3-17 INSTALLATION/SETUP

NOTE

Correct adjustment will result in the wire reel

circumference continuing no further than

20mm after release of the MIG Torch trigger

switch. The wire should be slack without be-

coming dislodged from the reel.

3.20 Shielding Gas Regulator Operating

Instructions

!

WARNING

This equipment is designed for use with weld-

ing grade (Inert) shielding gases only.

NOTE

Shielding Gas Regulator not included in the

Transmig 2RT.

NOTE

Shielding Gas is not required if the unit is

used with self shielded FCAW (flux cored arc

welding) wires.

Shielding Gas Regulator Safety

This regulator is designed to reduce and control high

pressure gas from a cylinder or pipeline to the working

pressure required for the equipment using it.
If the equipment is improperly used, hazardous

conditions are created that may cause accidents. It is

the users responsibility to prevent such conditions.

Before handing or using the equipment, understand and

comply at all times with the safe practices prescribed in

this instruction.

SPECIFIC PROCEDURES for the use of regulators are

listed below.

1. NEVER subject the regulator to inlet pressure

greater than its rated inlet pressure.

2. NEVER pressurize a regulator that has loose or

damaged parts or is in a questionable condition.

NEVER loosen a connection or attempt to remove

any part of a regulator until the gas pressure has

been relieved. Under pressure, gas can danger-

ously propel a loose part.

3. DO NOT remove the regulator from a cylinder

without first closing the cylinder valve and releas-

ing gas in the regulator high and low pressure

chambers.

4. DO NOT use the regulator as a control valve. When

downstream equipment is not in use for extended

periods of time, shut off the gas at the cylinder

valve and release the gas from the equipment.

5. OPEN the cylinder valve SLOWLY. Close after use.

User Responsibilities

This equipment will perform safely and reliable only when

installed, operated, maintained, and repaired in accor-

dance with the instructions provided. Equipment must be

checked periodically and repaired, replaced, or reset as

necessary for continued safe and reliable performance.

Defective equipment should not be used. Parts that are

broken, missing, obviously worn, distorted, or contami-

nated should be replaced immediately.
The user of this equipment will generally have the sole

responsibility for any malfunction, which results from

improper use, faulty maintenance, or by repair by anyone

other than an accredited repairer.

CAUTION

Match regulator to cylinder. NEVER CONNECT

a regulator designed for a particular gas or

gases to a cylinder containing any other gas.

LOW PRESSURE

GAUGE (DELIVERY)

HIGH PRESSURE

GAUGE (SUPPLY)

INLET

CONNECTION

OUTLET

CONNECTION

PRESSURE

ADJUSTING

SCREW

Art # A-10108

Figure 3-17: Adjusting Flow Rate

NOTE

The regulator/flow meters used with argon

based and carbon dioxide shielding gases are

different. The regulator/flow meter supplied

with certain Transmig 250i welders is for argon

based shielding gases. If carbon dioxide is to

be used a suitable carbon dioxide regulator/

flow meter will need to be fitted.