TRANSMIG 2RT

INSTALLATION/SETUP

INSTALLATION/SETUP 3-8

Manual 0-5196

3.09 Wire Feeder Set Up MIG (GMAW) Welding with Gas Shielded MIG Wire

The Transmig 250i is supplied with a Tweco Fusion 250 AMP air-cooled MIG Torch that can be used with the 2RT Wire

Feeder. The Fusion MIG Torch is designed with an ergonomic handle and fewer parts to cause performance problems.

The Fusion MIG Torch uses standard readily available Tweco Fusion consumable parts.
When using a Gas Shielded wire with the 2RT Wire Feeder, you need to have an external gas source attached to the 2RT.
For most Gas Shielded wire, connect the Work Lead to the negative - terminal on the front of the Transmig 250i and

connect the Welding Power Cable from the back of the 2RT to the positive + terminal on the front of the Transmig

250i. Check with wire manufacturer for recommended polarity.
The 2RT Wire Feeder is fitted with an 8M interconnection cable assembly to connect from the back of the 2RT to the

front of the Transmig 250i welding power source.
Connect the MIG Torch to the front of the 2RT as you would to the front of the Transmig 250i. See Figure 3-6 below

and Section 3.11.

+

-

Front View 2RT

Rear View 2RT

Front View 250i

Control Cable

Welding Power Cable

from Wire Feeder

Work Lead

Art # 10335

Gas Hose

Figure 3-6: Setup for 2RT Wirefeeder with Gas Shielded MIG Wire

WARNING

Before connecting the work clamp to the work make sure the mains power supply is switched off.

CAUTION

Loose welding terminal connections can cause overheating and result in the male plug being fused in the

terminal.

NOTE

Depending on the type of wire you will be using the MIG Torch polarity may need to be switched. Follow

the wire manufacturers recommendation.

NOTE

Spool hub and feed plate set up and operation are the same as the 250i which can be reviewed later in this

Section starting at 3.12.