The use of larger diameter wire makes welding difficult. The results cannot be guaranteed. The manufacturer
DOES NOT recommend using larger diameter welding wire with this unit.
WELDER OPERATING CHARACTERISTICS
The duty rating defines how long the user can weld and how long the welder must rest and cool down. Duty
Cycle ratings are expressed as a percentage of a ten-minute period. It represents the maximum welding time
allowed at the specified amperage setting. The remaining balance of a ten-minute period is required for cooling
off the unit.
All Firepower 230 volt Welding Systems are rated at the required input amperage for proper operation. Please
refer to the data plate located on the front of the unit for the specific rating that applies to your unit.
INTERNAL THERMAL OVERLOAD PROTECTION
DO NOT constantly exceed the duty cycle or damage could result to your welder.
If you do exceed the duty cycle of your welder, the internal thermal overload protection shuts
off all welder functions. If this happens, DO NOT SHUT OFF THE WELDER. Leave the
welder turned on and the fan running. After the welder is properly cooled, the thermal protec-
tor automatically resets and your welder will function properly.
If you find that your welder does not weld for a 1-5 minute time period without stopping, reduce the wire
speed slightly. Welding with the wire speed set too high not only causes poor visible welds but also increases
amperage draw and shortens the duty cycle.
SPECIFICATIONS FOR FP 200 WIRE(GMAW/FCAW) WELDING SYSTEM (1444-0310)
Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .185 AMP MIG Welding System
Input Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .230 Volt (60 Hz)
Rated Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .155 Amps @ 60% Duty Cycle
Agency Approval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .CSA Rating 60 Amps @ 20% Duty Cycle
Maximum Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .200 Amps Peak
Output Power Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Seven Position (Rotary Switch)
Wire Speed Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Infinite Speed Controlled by Potentiometer
Overload Indicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Illuminated Pilot Light
Power Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Illuminated ON/OFF Switch
Power Cord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 foot 50 Amp
MIG Gun . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 foot FIREPOWER® with ON/OFF Contactor Control
Ground Cable and Clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 foot Ground Cable/200 Amp Ground Clamp
Gas Solenoid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Installed
Spool Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .External Adapter (Installed) 2 lb, 10 lb, 30 lb
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Wheel Kit
1 lb. .030 MIG Wire
FIREPOWER® Gas Regulator
FIREPOWER® MIG Gun
Instruction Manual
SPECIFICATIONS FOR FP 260 WIRE(GMAW/FCAW) WELDING SYSTEM (1444-0312)
Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .250 AMP MIG Welding System
Input Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .230 Volt (60 Hz)
Rated Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .200 Amps @ 60% Duty Cycle
Agency Approval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .CSA Rating 60 Amps @ 60% Duty Cycle