4 gas connections, 4 gas connections -3 – Tweco PC-800 User Manual
Page 21
Advertising
Manual 0-4603
3-3
INSTALLATION
3.4
Gas Connections
A. Connecting Gas Supply to Unit
The connection is the same for compressed air or high pressure cylinders. Refer to subsection 3.4-B if a single-stage
air line filter is to be installed.
1. Connect the air line to the inlet port. The illustration shows typical fittings as an example. Other fittings may be
used.
NOTE
For a secure seal, apply thread sealant to the fitting threads, according to manufacturer's instructions. Do not use
Teflon tape as a thread sealer, as small particles of the tape may break off and block the small air passages in the torch.
Art # A-02999
Hose Clamp
1/4 NPT to 1/4"
(6mm) Fitting
Regulator/Filter
Assembly
Inlet Port
Gas Supply
Hose
Bowl
Air Connection to Inlet Port