OPERATION
4-4
Manual 0-4603
G. Set Operating Pressure
1.
Place the Power Supply RUN / Rapid Auto Restart / SET switch to the SET (down) position. Gas will flow.
Art # A-03592
A
20
40
60
1
2
2.
Adjust gas pressure at the power supply regulator.
Leads
Length
SL60
Hand Torch
20' / 6.1 m
70 psi
4.8 bar
PC-800 Air
Pressure Settings
Art # A-03829
70 psi / 4.8 bar
Pressure Control Knob /
Bouton De Contrôle
de Pression