Tweco PC-800 User Manual

Page 30

Advertising
background image

OPERATION

4-4

Manual 0-4603

G. Set Operating Pressure

1.

Place the Power Supply RUN / Rapid Auto Restart / SET switch to the SET (down) position. Gas will flow.

Art # A-03592

A

20

40

60

1

2

2.

Adjust gas pressure at the power supply regulator.

Leads

Length

SL60

Hand Torch

20' / 6.1 m

70 psi

4.8 bar

PC-800 Air

Pressure Settings

Art # A-03829

70 psi / 4.8 bar

Pressure Control Knob /
Bouton De Contrôle
de Pression