7. Actual input voltage does not correspond to voltage of unit
a. Verify that the input line voltage is correct. Refer to Section 2, Input Wiring Requirements.
8 . Faulty components in unit
a. Return for repair or have qualified technician repair per Service Manual.
B. Gas flows continuously when power is turned on, AC indicator
flashes
1. Torch switch is activated (closed) before user turns power on.
a. Release torch switch.
2. Faulty torch switch
a. Check torch switch for continuity. Replace if necessary.
C. Gas flows continuously; Torch will not pilot when torch switch is activated; AC indicator
ON
1. System is in SET mode
a. Change RUN / Rapid Auto Restart / SET switch to RUN (up).
D. No gas flow; RUN / Rapid Auto Restart / SET switch in SET position; Fans operate; AC indicator
ON;
GAS indicator
OFF
1. Gas not connected
a. Check gas connections.
2. Gas pressure too low for power supply operation
a. Adjust gas pressure per torch manual.
3. Faulty components in unit
a. Return for repair or have qualified technician repair.
E. Torch will not pilot; gas flows; AC indicator
ON, GAS
, TEMP , and DC
indicators OFF
1. Gas pressure is below power supply minimum requirement.
a. Adjust pressure to 70 psi / 4.8 bar.
F. Torch will not pilot; gas flows; AC
and Gas indicators
ON; DC
and TEMP indicators OFF
1. Gas pressure is below torch minimum requirement (Minimum pressure for power supply operation is lower than mini-
mum required for torch operation.)
a. Adjust gas pressure per torch manual.
G. Torch will not pilot; no gas flow; AC indicator
ON, GAS indicator
ON, DC indicator
ON
1. Starter cartridge missing from torch
a. Shut off power supply. Remove shield cup, install starter cartridge. Reinstall torch tip and shield cup. Turn
power supply ON / OFF switch to ON (up).