Tweco PC-800 User Manual

Page 39

Advertising
background image

Manual 0-4603

5-7

SERVICE

2. Shield cup is loose on torch

a. Check shield cup; tighten if necessary.

NOTE

When operating the torch in a normal condition, a small amount of gas vents through the gap between the shield cup and
torch handle. Do not attempt to over tighten the shield cup as irreparable damage to internal components may result.

3. Upper O-ring on torch head is in wrong position.

a. Remove shield cup from torch; check position of upper O-ring. Correct if necessary.

Lower O-Ring

Upper O-Ring
in Correct Groove

Upper Groove
with Vent Holes
Must Remain Open

Threads

Art # A-03640

H. Torch will not pilot; AC

, GAS

, and TEMP indicators ON, DC

indicator OFF

1. Air flow blocked

a. Check for blocked air flow around the unit and correct condition.

2. Unit is overheated

a. Let unit cool down for at least 5 minutes. Make sure the unit has not been operated beyond Duty Cycle limit.

Refer to duty cycle data in Section 2.

3. Input line voltage is low

a. Check and connect to proper input power line.

4. Faulty components in unit

a. Return for repair or have qualified technician repair per Service Manual.

I.

Torch cannot be activated; AC indicator

flashing; Gas indicator

ON; Temp indicator

OFF; DC

indicator

OFF

1. System is in protective interlock mode. (User held torch trigger while turning on ON / OFF switch.)

a. Release torch trigger.