Robotic Deflection Mount

3-9

SM-RDM-20000

inStAllAtion AnD opeRAtion

3.03 Wiring Diagram

The RDM-2000 Series deflection mount uses a single

normally closed, switch to determine the deflection

breakaway. Since the circuit is normally closed, the

emergency stop relay will be on during operation. If the

power is lost, a wire breaks, or if there is a collision, the

circuit will break telling the robot to stop. (If a normally

open circuit is desired, use the white wire instead of the

brown.) Refer to the diagram below.

RDM 2000 SeRieS
Deflection Mount
noRMAl opeRAtion

noRMAlly cloSeD

coMMon

noRMAlly open

bRoWn

gReen

White

Robot contRol
Shock SenSoR
ciRcuit

coMMon

optionAl
noRMAlly
open ciRcuit

3.04 Maintenance

The RDM-2000 Series deflection mount is designed to

operate in the most rugged industrial environments with

a minimum of maintenance. We recommend that the user

does not attempt to disassemble the mount other than

those steps required to attach the unit to the robot arm.

!

WARNING

Do not AtteMpt to open the RDM Deflection

Mount. the poWeRful coMpReSSeD SpRing

contAineD Within cAn cAuSe inJuRy if

DiSASSeMbleD iMpRopeRly. it iS RecoMMenDeD

thAt the RDM Deflection MountS be RetuRneD

to the fActoRy foR RepAiRS.

Figure 13: Exploded View of Internal Components