03 leak testing the system, Leak testing the system -15 – Tweco Single & Two Stage Regulators User Manual

Page 19

Advertising
background image

3-15

3.03 LEAK TESTING THE SYSTEM
Leak test the system before putting into operation.
1. Be sure that there is a valve in the downstream equipment to

turn off the gas flow.

2. With the cylinder valve open, adjust the regulator to deliver the

maximum required delivery pressure.

3. Close the cylinder valve.
4. Turn the adjusting screw/knob counterclockwise one turn.

a) If the high-pressure gauge reading drops, there is a leak

in the cylinder valve, inlet fitting, or high-pressure gauge.

b) If the low-pressure gauge drops, there is a leak in the

down stream equipment, hose, hose fitting, outlet fitting or

low-pressure gauge. Check for leaks using an approved

leak detector solution.

c) If the high-pressure gauge drops and the low-pressure

gauge increases at the same time, there is a leak in the

regulator seat.

d) If the regulator requires service or repair, take it to a

qualified repair technician.

5. Once leak testing has been performed and there are no leaks

in the system, slowly open the cylinder valve and proceed.

WARNING

If a leak has been detected anywhere in the system, dis-

continue use and have the system repaired. DO NOT use

leaking equipment. Do not attempt to repair a leaking

system while the system is under pressure.