Manual 0-5160

NOTE:

To make it easier to remove and install the new PCB it is recommended that you dismount the contactor

leaving all wires attached and pull it out away from the PCB. This will give more room to maneuver

the PCB.
If you are working on a CE unit with a CE filter to the right of the contactor then you will need to remove

the filter to access a mounting screw on the PCB.

6. Remove the (15) screws from the Capacitor PCB.

Set the screws aside for reattachment later.

NOTE:

There are two screws that are different from the rest. These screws must be used in the same HS5 and

HS6 locations when reassembling.

Capacitor PCB

HS5 and HS6 locations

Main PCB

40A or 50A PCB

Art # A-09331_AB

Devices will not be present on some models

If you are only replacing the Capacitor PCB then proceed to “Capacitor PCB Installation”