Tweco 7-5227 User Manual

Page 2

Advertising
background image

July 28, 2004

2

Manual 0-4647

C. Current Rating (Refer to Note)

NOTE

Power Supply characteristics will determine ma-
terial thickness range.

SL60 & SL100 Current Ratings

SL60 Torch & Leads

SL100 Torch & Leads

Up to 60 Amps, DC,
Straight Polarity
Up to 100 Amps, DC,
Straight Polarity

D. Torch Ratings

Ambient

Temperature

104° F

40° C

Duty Cycle

100% @ 60 Amps @ 400 scfh

Maximum Current

60 Amps

Voltage (V

peak

)

500V

Arc Striking Voltage

7kV

SL60 Torch Ratings

Ambient

Temperature

104° F

40° C

Duty Cycle

100% @ 100 Amps @ 400 scfh

Maximum Current

100 Amps

Voltage (V

peak

)

500V

Arc Striking Voltage

7kV

SL100 Torch Ratings

E. Type of Cooling

Combination of ambient air and gas stream through torch.

F. Gas Requirements

Gas (Plasma and Secondary)

Compressed Air

Operating Pressure
Refer to NOTE

60 - 75 psi

4.1 - 5.2 bar

Maximum Input Pressure

125 psi / 8.6 bar

Gas Flow (Cutting and Gouging)

300 - 500 scfh

(142 - 235 lpm)

SL60 and SL100 Torch Gas Specifications

WARNING

This torch is not to be used with oxygen (O

2

).

NOTE

Operating pressure varies with torch model and
operating amperage. Refer to gas pressure settings
chart for each model.

G. Direct Contact Hazard

For exposed tip the recommended standoff is 1/8" - 1/4" (3 - 6.4
mm).

H. Parts-In-Place (PIP) Circuit - 12 vdc

The torch and leads include circuitry called Parts-In-Place
(PIP). This circuit includes a switch located at the torch
head. The shield cup closes this switch when properly
installed. The torch will not operate if this switch is open.

A-02997

Torch Trigger

PIP Switch

Shield Cup

To Control

Cable Wiring

Torch Switch

Advertising