Tweco XT-301 Torch Data for OEM Use w- Auto-Cut 100 AD User Manual

Page 14

Advertising
background image

Torch Data

8-14

Manual 0-4734 Rev. AD

Aluminum

100A

N2 Plasma / H20 Shield

Plasma

(N2)

Shield

(H2O)

(ga)

(in)

inch

psi

Ball *

Volts

(in)

±0.005

(ipm)

(in)

(sec)

(in)

10

0.135

100

5

148

0.125

170

0.200

0.0

0.072

3/16

0.188

100

5

158

0.125

80

0.250

0.3

0.080

1/4

0.250

100

5

158

0.125

60

0.250

0.3

0.085

3/8

0.375

100

5

161

0.125

50

0.250

0.3

0.086

1/2

0.500

100

5

170

0.130

35

0.300

0.6

0.091

5/8

0.625

100

5

180

0.140

20

0.300

0.8

0.120

Plasma

(N2)

Shield

(H2O)

bar

Ball *

Volts

(mm)

±0.1

(mm/min)

(mm)

(sec)

(mm)

6.9

5

152

3.2

3350

5.6

0.1

1.9

6.9

5

158

3.2

1960

6.4

0.3

2.1

6.9

5

158

3.2

1640

6.4

0.3

2.1

6.9

5

160

3.2

1390

6.4

0.3

2.2

6.9

5

162

3.2

1210

6.5

0.3

2.2

6.9

5

168

3.3

970

7.3

0.5

2.3

6.9

5

177

3.5

610

7.6

0.7

2.8

NOTE: Ohmic height sensing is not recommended with water shield.

Water on the plate interferes electrically with the ohmic sensing circuit.

* Ball setting for shield water is set using a line pressure of 55 psi / 3.8 bar.

8

10

12

15

(mm)

4

5

6

Material

Thickness

Cut Flow Pressures

Arc

Voltage

Torch

Working

Height

Travel

Speed

Initial

Piercing

Height

Pierce

Delay

Kerf

Width

@ Rec.

Speed

100A Aluminum (N2/H2O)

Material

Thickness

Cut Flow Pressures

Arc

Voltage

Torch

Working

Height

Travel

Speed

Initial

Piercing

Height

Pierce

Delay

Kerf

Width

@ Rec.

Speed

Cartridge

36-1020

Shield Cup

36-1016

Shield Cap

36-1034

Shield

Gas Distributor

36-1272

Tip

36-1053

Plasma

Gas Distributor

36-1041

Electrode

36-1089

Art # A-07177

Advertising