2 power requirements, 3 site wiring requirements, Power requirements – Unitec Portal Installation Manual User Manual

Page 10: Site wiring requirements

Advertising
background image

P O R T A L T I

Portal Installation Manual Rev C

6

Document #: PTL1001

1.4.2 Power Requirements

The Portal requires 120 VAC, 8 Amps service. In applications where barrier gates
are to be used, each gate requires 120 VAC, 5 Amps service. The Portal and Gate
must be powered from separate circuits.

Note:

Ensure the protective earth ground wires do not carry any motor return current. Only
the neutral wire should carry return current. Follow local electrical code when wiring
the Portal TI.

1.4.3 Site Wiring Requirements

Wiring requirements will vary by site depending on the type of wash equipment and
the Portal configuration. The following table shows site wiring, which may be needed.
As wires are pulled through conduit, ensure there is at least 6 ft. of wire extending
from the end of the conduit stub.

Circuit Description

Wire Qty

Wire Requirements

Portal Power (115-120 VAC, 8 Amps).

3

16 AWG minimum, black/white/green

Gate Power (115-120 VAC, 5 Amps).

3

16 AWG minimum, black/white/green

Network connection (to router)

1

Cat 5 communications cable, 295 ft max length

Wash Signaling (required if the Portal will be

connected to the wash controller)

Varies

Refer to wash equipment manufacturer’s

instructions

Phone Line

(required for dial-up credit option)

1

2 Pair / 4 Conductor Telephone Cable

Intercom

(Required to interface with site intercom)

4

22 AWG minimum

Camera

(Required for Portal camera option)

1

Type RG59/U coaxial cable

Gate Control – from gate controller to Portal

(Required if gate controller is used)

4

18 AWG minimum

Gate Control - from gate controller to gate

(Required if gate controller is used)

3

18 AWG minimum

Gate Control – from Portal to Gate

(Required if gate is used without gate controller)

4

18 AWG minimum

RFID Option

(from RFID Antenna to Portal)

1

Cable is supplied with RFID kit

Advertising