Figure 21. 6-pin phoenix connector – Unitec Portal Installation Manual User Manual

Page 30

Advertising
background image

P O R T A L T I

Portal Installation Manual Rev C

26

• You will need a thin tipped, flat head screwdriver to open and tighten the relay

connections of the Phoenix connector.

• Review the wash manufacturer’s documentation to determine the color codes for the

wiring of the wash pin-outs for your wash equipment before beginning this installation.

• Phoenix connectors are shipped already inserted in the appropriate sockets on the

Wash I/O board.

1. On the Wash I/O Board, locate the 6-pin Phoenix connector labeled J18 on the

lower left-hand corner of the Wash I/O board.

2. Remove the Phoenix connector from the socket.

3. Turn the connector so that the wire inputs are facing up as shown below.

Figure 21. 6-Pin Phoenix Connector

4. Referring to the figure above, connect the following wires to the appropriate pins,

as indicated in the following table. Use the screwdriver to open and/or secure the
manufacturer wash wires to each of the Unitec relay locations.

Wash-In-Use Connections

Pin

Signal

Pin 1

Wash-In-Use Hot

Pin 2

Wash-In-Use Neutral

Pin 3

Wash-Fault-Hot

Pin 4

Wash-Fault-Neutral

Pin 5

Wash-Complete-Hot

Pin 6

Wash-Complete-Neutral

5. Plug the Phoenix connector into the Wash I/O board socket J18.

6. Replace the protective metal plate that covers the Wash I/O board and the carrier

board.

Document #: PTL1001

Advertising