Mute, Meters and volume, Adjusting volume – ClearOne Interact Manual User Manual

Page 35: Learn about using meters, Camera control, Camera control settings, To open the camera control window, To set camera presets, To test camera presets, Eters

Advertising
background image

30

Technical Support: 800-283-5936

Mute

• Press the Mute button to silence audio on the Line Input.

Meters and Volume

a

djusTing

v

oluMe

1. Get an Audio Signal from the Line Input device.
2. Adjust the Audio Level using the Volume slider.

l

earn

abouT

u

sing

M

eTers

• The Peak Meters are used to measure the Audio Level with the meter bars moving from green to yellow

to red as the volume increases. The red bars indicate that the audio is too loud and is being clipped or
cut off.

CAMERA CONTROL

The INTERACT system provides voice tracking capabilities through VISCA control port connection to a
PTZ camera. The camera presets are programmed within the INTERACT Software and assigned to each
microphone pod. The INTERACT AT supports nine camera positions as well as a home position.

Camera Control Settings

T

o

o

pen

The

C

aMera

C

onTrol

w

indow

• With the camera connected, click the Camera Controls button on the configuration window.

T

o

s

eT

C

aMera

p

reseTs

1. Select the Camera Control Mode, either Sony or Cannon.
2. If you have more than one camera, select which camera you are programming.
3. Select the Camera Delay. Camera Delay is the amount of time the microphone must be activated

before the camera moves to the preset position.

4. Select Voice Tracking System Enabled.
5. Using the Directional Arrow buttons and the Zoom In and Zoom Out buttons, position the camera for

the first microphone pod.

6. Click Save Preset under the microphone pod to assign the camera position to the microphone.
7. Repeat steps 1-6 for the second and third microphones.

T

o

T

esT

C

aMera

p

reseTs

• Click Run Preset to test the preset programming for the microphone pod.

Advertising